Graphtec Petit LOGGER GL100-N Data Logger w/ Thermistor & Logic Terminal

The GL100-N data logger comes with a 4 channel thermistor for industries requiring climate monitoring and control such as greenhouse, hydroponics, agriculture and botanical rooms gives managers real time environment and climate monitoring.
Easy connection to PC

GL100-N Features
- Modular
- Supports a variety of measurements by exchanging the input module
- PC and smart mobile device software available
- Industry-specific software: agriculture, logistics, power
- Built-in memory ~4.9MB
- microSD memory card port
Applications

Technical Specifications
|
Specifications of GL100-N
|
|
Item
|
Description
|
|
Number of channel
|
Up to 4 channels (varies by the type of input module used, and measurement type is fixed with each input module.)
|
|
Interface to PC
|
USB 2.0
|
|
Functions
|
• Real-time data capturing • Display the captured data value to the LCD in real-time and save the monitoring values • Set conditions using the Menu setting
|
|
While using USB port: • Output captured data in real-time • Output the saved data from the internal memory • Full control of the GL100 from the PC application software
|
|
Display
|
LCD (backlit monochrome, graphical type)
|
|
Storage device
|
• Built-in RAM (Approx. 4.9 MB) • micro SD memory card * Maximum file size for captured data is 1.9 GB.
|
|
Sampling interval
|
0.5 to 30 seconds and 1 to 60 minutes
|
|
Output signal
|
Alarm (1 channel)
|
|
Power source
|
• Battery (AA x 2) • USB bus-power (micro USB connector) * The required power capacity is 5V, 1A when AC adapter for microUSB drive is used. AC adapter is not included.
|
|
Operating environment
|
Temperature: -10 ºC to 50 ºC Humidity: up to 80% RH (non condensed) Water resistance: IP54
|
|
External dimension
|
Approx. 66 x 100 x 27 mm (exclude protrusion)
|
|
Weight
|
GL100-N: Approx. 125 g, GL100-WL: Approx. 130 g
|
|
Software
|
|
Item
|
Description
|
|
Supported OS
|
Windows: 8.1 / 8 / 7 / Vista (32- or 64-bit), Android OS: 4.3 or later, iOS: 7 or later
|
|
Controlled units
|
Up to 10 units
|
|
Accessories
|
|
Item
|
Model number
|
Description
|
|
Thermistor sensor (Normal type)
|
GS-103AT-4P
|
Sensor for GS-4TSR module, 3 m, 4 pcs/set, Temp. range: -40 to 105 ºC
|
|
Thermistor sensor (Ultrathin type)
|
GS-103JT-4P
|
Sensor for GS-4TSR module, 3 m, 4 pcs/set, Temp. range: -40 to 120 ºC
|
|
AC Current sensor
|
GS-AC50A
|
For GS-DAP-AC module, Cable 200 mm, Current range : 50 A AC
|
|
AC Current sensor
|
GS-AC100A
|
For GS-DAP-AC module, Cable 200 mm, Current range : 100 A AC
|
|
AC Current sensor
|
GS-AC200A
|
For GS-DAP-AC module, Cable 200 mm, Current range : 200 A AC
|
|
Dual port adapter
|
GS-DPA
|
Connect up to two (2) sensors
|
|
Module Extension Cable
|
GS-EXC
|
Extension cable for input module, 1.5 m long
|
|
Item
|
Description |
|
GS-4TSR
|
Supports two optional thermistor types (GA-103AT-4P and GS-103JT-4P), terminal with up to 4 cha of temperature measurement (-40.0º to 105.0ºC; GS103AT-4Ptime) or (-40.0º to 120.0ºC; GS-103JT-4Ptime). Any combination of pulse and logic channels may be measured at the same time. |
| |
|
Measurement Data
|
Temperature, Logic/Pulse (instant and accumulated) |
| |
|
Measurement ch
|
Temperature |
4ch(1)
|
| Logic/Pulse Count |
4ch(1)
|
|
Input Method
|
Scans using photo-MOS relay. All channels are non-isolated input. |
|
Range of Temperature Measurement
|
Supports two types of thermistors Type A: -40.0º to 105.0ºC; GS103AT-4Ptime Type B: -40.0º to 120.0ºC; GS-103JT-4Ptime |
|
Temperature Measurement Accuracy
|
Main Unit |
-40 ≤TS <0ºC ± 0.7ºC 0 ≤TS ≤35ºC ± 0.2ºC 35 < TS ≤70ºC ± 0.4ºC 70 < TS ≤120ºC ± 1.0ºC
|
| Thermistor |
±0.4ºC (represented value) GS-103AT-4P / GS103JT-4P
|
|
Logic / Pulse Input
|
Input Voltage Range |
0 to +24V (single line ground input)
|
| Input Signal |
Wireless pressure point(2), open corrector, voltage input
|
| Input Voltage Threshold |
Approximately +2.5V
|
| Hysteresis |
Approximately 0.5V (+2v to +2.5V)
|
|
Range of Pulse Measurement
|
Instant count: Maximum 200C / sampling interval Accumulated value: Maximum 65535C(3) |
|
Temperature Unit of Denomination
|
ºC / ºF (selectable) |
|
Sampling Intervals
|
0.5 | 1 | 2 | 5 | 10 | 20 | 30 sec 1 | 2 | 5 | 10 | 20 | 30 | 60 min |
|
Processor Functionality
|
Luminance |
0 to 999,999 klxh
|
| UV Ray |
0 to 999,999W/cm2 (2)
|
|
Sampling Intervals
|
0.5 | 1 | 2 | 5 | 10 | 20 | 30 sec 1 | 2 | 5 | 10 | 20 | 30 | 60 min
|
|
Extension Cable
|
Approx 200mm
|
|
Operating Environment
|
-10º to 50ºC, 80% RH and below (non-condensed) |
|
External Dimensions
|
46mm x 66mm x 35.5mm (excludes protrusion) |
|
Weight
|
83g (2.92 oz) |
(1) Measurement type for each channel can be seperately selected. (2) A contact point, b contact point, NO, NC. (3) Clear accumulated value by QUIT key or when starting recording.
|
The Graphtec GL100-N is a compact data logger that goes up to 4 channels.
| |