Vaisala HMT120 Humidity and Temperature Transmitter
|
Item Number: HMT120
Configuration: HMT120-H-A-0-A-1-A-1-1-A-1-A-0-Z
Manufacturer: Vaisala
Part Number: HMT120
Product Options
* denotes required field
HMT120 Output Parameter Options*
You must select an option for 'HMT120 Output Parameter Options'.
HMT120 Transmitter Probe Configuration*
You must select an option for 'HMT120 Transmitter Probe Configuration'.
HMT120 Display Option*
You must select an option for 'HMT120 Display Option'.
HMT120 Parameter for Output 1 Selection*
You must select an option for 'HMT120 Parameter for Output 1 Selection'.
HMT120 Parameter for Output 2 Selection*
You must select an option for 'HMT120 Parameter for Output 2 Selection'.
HMT120 Display Unit Options*
You must select an option for 'HMT120 Display Unit Options'.
HMT120 Sensor Protection Options*
You must select an option for 'HMT120 Sensor Protection Options'.
HMT120 Transmitter installation Option*
You must select an option for 'HMT120 Transmitter installation Option'.
HMT120 Installation kit for probe Selection*
You must select an option for 'HMT120 Installation kit for probe Selection'.
HMT120 Cable Bushings Selection*
You must select an option for 'HMT120 Cable Bushings Selection'.
HMT120 PC Accessories Option*
You must select an option for 'HMT120 PC Accessories Option'.
HMT120 Calibration Options
* Whole number only
|
|
Vaisala HMT120 Humidity and Temperature Transmitter
The Vaisala HUMICAP® Humidity and Temperature Transmitters HMT120 and HMT130 are designed for humidity and temperature monitoring in cleanrooms and are also suitable for demanding HVAC and light industrial applications.
Features
- Vaisala HUMICAP® technology with humidity sensor HUMICAP® 180R
- 2-wire loop-powered or 3-wire voltage output configurations
- Interchangeable probe (easy field calibration)
- Accurate and reliable
- Resistant to dust and most chemicals
- Optional LCD display
- USB cable available for a PC connection for maintenance
- Wall-mounted or with a remote probe
- Can be mounted outdoors using a Vaisala installation kit and the Vaisala Radiation Shield DTR502B
- Enclosure IP65
- Suitable for cleanrooms and demanding HVAC applications
Technical Specifications
Relative humidity
|
| |
Measurement range |
0 ... 100 %RH |
| |
Accuracy including non-linearity, hysteresis, and repeatability at 0 °C ... +40 °C |
±1.7 %RH (0 ... 90 %RH) |
| |
|
±2.5 %RH (90 ... 100 %RH) |
| |
at -40 °C ... +0 °C and at +40 °C ... +80 °C Factory calibration uncertainty at +20 °C (+68 °F) |
±3.0 %RH (0 ... 90 %RH) ±4.0 %RH (90 ... 100 %RH) ±1.5 %RH |
| |
Humidity sensor |
Vaisala HUMICAP® 180R |
| |
Stability |
±2 %RH over 2 years |
Temperature
|
| |
Measurement range |
-40 ... +80 °C |
| |
Accuracy over temperature range at +15 °C ... +25 °C at 0 ... +15 °C and at +25 °C ... +40°C at -40 °C ... +0 °C and at +40 °C ... +80 °C |
±0.2 °C ±0.25 °C ±0.4 °C |
| |
Temperature Sensor
Operating temperature range
|
Pt1000 RTD Class F0.1 IEC 60751
|
|
transmitter body, no display transmitter body, with display HMP110 probe Storage temperature range Electromagnetic compatibility |
-40 °C ... +60 °C -20 °C ... +60 °C -40 °C ... +80 °C -50 °C ... +70 °C EN 61326-1 and EN 55022
|
Inputs and outputs
HMT120 TWO-WIRE TRANSMITTER (LOOP POWERED) |
|
|
Current output signals External loop voltage
HMT130 THREE-WIRE TRANSMITTER Voltage output signals
Min output resistance Serial output Relay output Supply voltage
Current consumption at 24 VDC Max. additional error caused by the analog outputs after calibration at +20 °C ambient temperature
|
4 ... 20 mA 10 ... 30 VDC (RL= 0 ohms) 20 ... 30 VDC (RL< 500 ohms)
0 ... 1 V, 0 ... 5 V, 0 ... 10 V or user defined between 0 ... 10 V 1 kohm RS485, non-isolated 1 relay (max. 50 VDC, 200 mA) 10 ... 35 VDC 15 ... 35 VDC (when output 0 ... 10 V) 24 VAC (±20 %) 8 mA, if relay closed 15 mA ±0.1 % of FS output signal |
|
Temperature dependence of the analog outputs
|
±0.005 % of FS output signal |
|
Mechanics
Materials |
|
| |
transmitter housing display window |
PBT plastic PC plastic |
|
probe body |
Stainless steel (AISI 316) |
|
probe grid filter |
Chrome coated ABS plastic |
|
Housing classification |
IP65 |
|
Connections |
|
|
inputs and outputs |
Screw terminals 0.5 ... 1.5 mm2 |
|
probe interface
Probe cable length Display (optional)
Weight (including probe) |
4-pin M8 female panel connector 3 m, 5 m, 10 m - up to 50 m 128 x 64 resolution full graphics B&W display without backlight 270 g |
|
Vaisala HUMICAP® Humidity and Temperature Transmitters HMT130 is designed for humidity and temperature monitoring in cleanrooms and are also suitable for demanding HVAC and light industrial applications.
|
Vaisala HUMICAP® Humidity and Temperature Transmitters HMT120 is designed for humidity and temperature monitoring in cleanrooms and are also suitable for demanding HVAC and light industrial applications.
|
Vaisala HUMICAP® Humidity and Temperature Transmitters HMT130 is designed for humidity and temperature monitoring in cleanrooms and are also suitable for demanding HVAC and light industrial applications.
| |
Product Reviews
|
|