Simpson 228 Leakage Current Tester

Our Price: $696.07
Item Number: 40027
Manufacturer: Simpson
Part Number: 40027

Product Options

* denotes required field

NIST Traceable Calibration Certificate*
Simpson 228 Leakage Current Tester

Simpson 228 Leakage Current Tester

The 228 detects both AC and DC leakage current and simulates human response at three different levels -- reaction, let-go, and burn hazard. Each Model 228 comes with test leads with alligator clips, manual, and batteries.

Features:

  • Detects dangerous AC & DC leakage current present on the conductive surfaces of electrical or electronic equipment
  • Designed to meet new IEC, ANSI, and UL guidelines
  • Reaction, Let-Go and Unweighted Burn Hazard network measurements
  • Battery-powered for maximum portability .

Technical Specifications:

GENERAL 

Reaction
Response Network 

Let-Go
Response Network 

Unweighted Burn Hazard
Response Network 

Equivalent Network Component Values: 

Complies with values specified in IEC 990 (Excluding fuse) 

Equivalent Measuring Instrument Load: 

1 MOhm - 10pF 

1 MOhm - 62 pF 

1 MOhm - 1 pF 

Ranges: 

0.3, 1, 3, 10 M.I.U. 

0.3, 1, 3, 10 M.I.U.  

0-100 mA RMS 

Current Accuracy: 

+/- 2% F.S. @ 60 Hz 

Meter Measurement Method: 

True RMS 

Meter Frequency Response: 

(Relative to ANSI C101-1992 or UL-1459 2nd edition) 

   DC to 1 Hz

Pointer shall track within 5% of peak 

   2Hz to 19 Hz (Accuracy not supported)  
   20 Hz to 200 Hz

+/- 2% F.S. 

+/- 2.5% of F.S. 

+/- 2% F.S. 

   200 KHz to 1 MHz 

+/- 2% F.S. 

+/- 2.5% F.S. 

+/- 5% F.S. 

Output Sensitivity: 

Full scale meter indication equals 1V RMS (Measured with a 1 MOhm, 12 pF load) 

Output Accuracy: 

+/- 2% of reading @ 60 Hz 

Output Frequency Response: 

(Relative to ANSI C101-1992 or UL-1459 2nd edition) 

   DC to 50Hz 

+/- 2% of reading 

   50 Hz to 100 KHz

+/- 2.5% of reading 

+2%/-3% of reading 

+/-2% of reading 

   100 kHz to 1 MHz

+/- 5% of reading 

Voltmeter Range: 

0-300 V (AC or DC) 

Voltmeter Accuracy: DC to 1 Hz 

Pointer shall track within 5% of peak 

   2Hz to 19 Hz (Accuracy not supported)   
   20 Hz to 1 KHz

+/- 3% F.S. @ 60 Hz (Add +/- 1% for every additional 100 Hz) 

Voltmeter Frequency Response: 

DC to 1KHz 

Power Requirements: 

(2) 9V (NEDA 1604A) batteries 

Physical: 

7" x 5.25" x 3.125", 2-1/2 lbs (1.4kg), ABS plastic, fused input 

Enviornmental: 

27 Deg C +/- 2 Deg C, 70% non condensing relative humidity.   Outside range derate by 10% per Deg C 

Maximum Operating Range: 

0 Deg to 40 Deg 

Product Reviews

(0 Ratings, 0 Reviews)