Rotronic HygroClip HC2-SH Standard Climate Probe
|
Item Number: HC2-SH
Manufacturer: Rotronic
Part Number: 0210.HC2-SH
* Whole number only
|
|
Rotronic HygroClip HC2-SH Standard Climate ProbeFeatures
- Accuracy: ±0.5 %rh, ±0.1 K, at 23 °C ±5 K
- Range of application: -50…100 °C / 0…100 %rh
- Digital interface (UART) and scalable analog outputs, 0…1 V
- Standard output scaling: 0…1 V = -40…60 °C / 0…100 %rh
- Adjusted at 23 °C and 10, 20, 30, 40, 50, 60, 70, 80, 90 %rh, then calibrated at 20, 50, 80 %rh
Fast response • By decoupling the Pt100 temperature sensor from the probe, thermal response is significantly improved
Innovative filter technology • The latest in filter technology provides a high level of protection and maintains the optimum measurement environment for the Hygromer humidity and Pt100 temperature sensors
AirChip3000 • Compensates humidity and temperature over 30,000 reference points • 2,000 data point memory • Dew/frost point calculation • Sensor auto-diagnostics and automatic correction • Active alarming and information • ASIC (Application Specifi c Integrated Circuit), micro-controller and EEPROM on one chip
Maximum flexibility • The UART 1 interface and user scalable analog outputs allow the probe to be used as a stand-alone device that can also be effortlessly integrated into an OEM application • The probes can be interchanged without adjustment
1 Universal Asynchronous Receiver Transmitter
|
 |
Dimensions & Connections Technical Specifications
| Probe type |
Standard probe |
| Dimensions |
Ø15 x 83 mm |
| Weight |
10 g |
| Operating range electronics |
-50…100 °C / 0…100 %rh |
| Accuracy at 23 ±5 °C |
±0.5 %rh / ±0.1 K |
| Accuracy w. adjustment profile "High Precision" |
at 23 °C / 10, 20, 30, 40, 50, 60, 70, 80, 90 %rh ± 0.5 %rh / 0.1 K |
| Power supply / Power consumption |
3.2…5 VDC ±0 % / < 4.5 mA |
| Long-term stability sensor |
<1 %rh / year |
| Humidity sensor |
Hygromer IN-1 |
| Temperature sensor |
PT100 1/3 DIN Class B |
| Probe protection |
Polycarbonate plastic cage, black |
| Filter cartridge |
Polyethylene dust filter, gray, 20 um |
| Response time t 63 |
<15 sec. |
| Allowed wind speed |
20 m/s, with filtre |
| Psychrometric calculations |
Dew or frost point |
| Reproducibility Airchip |
<0.02 %rh / 0.01 K |
| Exploitation software |
ROTRONIC HW4.2 |
| Probe adjustment by software |
1 Point & multipoint %rh & °C |
| Firmware update |
With internet and HW4 software |
| User information |
from Software HW4 (devicemanager) |
| Data processing via HW4 |
with interface cables |
| Device Protection by password |
Yes |
| Type of output signals |
2 x 0…1 VDC |
| Analogue outputs scaleable by the user |
Yes |
| Analog output signal (standard) |
0…1 V = 0…100 %rh; 0…1 V = -40…60 °C |
| Digital output signal (standard) |
UART |
| Service Interface |
UART |
| Reverse voltage protection |
Mechanically in the connector |
| Max. cable length |
5 m |
| Enclosure material |
Polycarbonate |
| FDA/GAMP compatibility |
FDA 21 CFR Part 11 and GAMP compatible |
|
The Rotronic HC2-S probe has an accuracy of ±0.8 %rh, ±0.1 K, at 23 °C ±5 K.
| |