Newport CT485B Temperature Humidity Recorder
The new Model CT485B completely self-contained Temperature/relative humidity recorder is microprocessor based to accurately measure, indicate and record temperature and relative humidity. This rugged unit comes standard with alarms. They contain a single, integral relay contact which closes in response to an alarm condition. Simultaneous high and low alarm points for temperature and relative humidity are user selectable. When the current conditions exceed any of the preset values, the 2 Amp relay contact closes and an audible alarm sounds. Flipping open a hinged front panel door permits access to the power switch and controlling functions of the recorder. The door comes with a locking mechanism. The user may select 1, 7 or 32 day operation, program the instrument to record in ºC or ºF, and access alarm and calibration controls or max/min functions. A separate 3-position switch next to the digital display selects a ºC,ºF or %RH readout. The chart drive is stepper controlled for precision, and a unique magnetic retaining knob eliminates the possibility of paper tear. Calibration of alarm models is digital, and a user may make calibration adjustments in the field using the convenient panel pushbuttons. An optional calibration lockout cover prevents unauthorized changing of calibration codes. A stabilizing arm provides added stability for benchtop use. The arm conveniently rotates under the unit for wall mounting. Recessed rear mounting slots and a wall template enable easy wall mounting. A decorative cover for the stabilizing arm is supplied for wall mount use. A standard 110 Vac power adaptor is supplied for continuous long-term operation, along with four D-cell batteries for backup power or field use. Each unit includes 6 feet of cable for remotely mounting the sensor. A sensor holder clip is provided. Units come standard with two chart light bulbs and a display back light. When using the ac power adaptor, these bulbs provide easy viewing of the chart and display in dimly lit conditions. A switch is provided to allow the lights to be turned on or off. SPECIFICATIONS Measurement Inputs: Temperature and humidity, with plug-in external sensor, removable for remote location, 6' extension cable included; 0.02 to 1.20 Vdc signal with voltage input adaptor TEMPERATURE Range: -17 to 49 Deg C (2 to 120 Deg F) Accuracy: +/-1 Deg C Sensor: Solid state Response Time: 5 minutes for 63% step change Display Resolution: 1 Deg C/1 Deg F HUMIDITY Range: 2 to 98% RH Accuracy: +/-3% @25 Deg C, between 20 and 90% of range (+/-5% below 20% and above 90% @25 Deg C) Sensor: resistive polymer. Not recommended for use in corrosive air environments Response Time: 5 minutes for a 30 to 80% step change Display Resolution: 1% RH 2 1/2 digit LCD, 0.5" high; low battery Display Modes: Front panel switchable between Deg C, Deg F and %RH for continuous digital display; max/min storage for both temperature and humidity or flashing to indicate alarm condition ELECTRONICS Type: Microprocessor-controlled and linearized high and low peak hold for both temperature and humidity, re-initializes position at every chart change CHART Type: 8" circular, linear radial divisions; 1, 7 and 32 days, Deg C and Deg F scales CHART DRIVE Type: Stepper motor Ranges: 1, 7 and 32 day, selectable Accuracy: 1% of rotation Chart Hold Down: magnetic hub lock RECORDING PENS Type: Disposable fiber tip, red for temperature, blue for humidity PEN DRIVES Type: Motorized linear screw drive Deadband: 1 Deg F, 1% RH Zero: Automatic zero during chart change or power interruption Penlift: Automatic on door opening; pens are door mounted and swing clear of the chart when door opens Pen Arms: Clear plastic to allow full chart viewing OPERATING CONDITIONS (Recorder) Temperature: 0 to 49 Deg C (32 to 120 Deg F) Humidity: 0 to 90% RH, non-condensing OPERATING CONDITIONS (Sensor Remote) (Sensors not recommended for use in a corrosive environment) Temperature: -17 to 49 Deg C (2 to 120 Deg F) Humidity: 0 to 98% RH ALARMS Alarms: User-selectable for high or low temperature and humidity Audible Alarm: Integral piezoelectric beeper Alarm Relay Contacts: 1 Amp, 30 Vdc Normally open, single pole, single throw (SPST) Power (Recorder): Four D cells or 9Vdc/110, 50/60 Hz power adaptor (supplied); 220 Vac power adaptor supplied where applicable Battery Life: more than 1 month continuous operation in 32-day mode (average conditions) Power Requirements: 300 mA "normal" during pen movement for battery (dc) power; 500 mA "normal" during pen movement for ac power using ac adaptor with chart lights on (Note: the light bulbs drain 200 mA of current and the display back light drains 20 mA) DC Power Jack Voltage: 8.3 to 12.4 Vdc (nominal 9 Vdc), 1 Amp max. MECHANICAL Dimensions: 33.5 H x 27.1 W x 6.7 cm D (13 3/16" x 10 11/16" x 2 5/8") Weight: Approx. 3 Kg (7 lbs) including batteries Mounting: "Keyhole" slots for wall mounting; foot cover for benchtop use Case: Rugged ABS plastic ANALOG VOLTAGE INPUT ADAPTOR Input: 20 mVdc to 1200 mVdc records as 2 to 120 Deg F, input protection up to 20 Vdc or 10 Vac RMS Input Impedance: 330 Kohms min. Input Connections: Banana jacks, 19 mm (0.75") spacing Cable Length: 305 mm (12")
|
Replacement pen set for Newport CT485B circular chart recorder. Includes 1 red (temperature) and 1 blue (humidity) pen.
|
Standard Chart Paper (double-sided - available as single package of 100 or 6 packages of 100 Charts - NEW CHARTS AVAILABLE WITH 24 HR TIME! Call for special lab, hospital, clean room and museum charts.
|
Retaining the legendary CT-485 design, the CTXL Series comprises state-of-the-art circular chart recorders, available in 3 models- CTXL-TRH, CTXL-DTC, and CTXL-DPR.
| |
Product Reviews
|
|