| | |
|
| |
| | |
|








|
Newport i32 - 1/32 DIN Temperature, Process, PID Controller, Indicator
|
Item Number: i32
Manufacturer: Newport Electronics
Part Number: i32
Product Options
* denotes required field
Newport I Series Control Ouput Selection*
You must select an option for 'Newport I Series Control Ouput Selection'.
Newport I Series Serial Output Option*
You must select an option for 'Newport I Series Serial Output Option'.
Newport I Series Power Supply Selection*
You must select an option for 'Newport I Series Power Supply Selection'.
Newport I Series Calibration*
You must select an option for 'Newport I Series Calibration'.
* Whole number only
|
|
Newport i32 - 1/32 DIN PID Controller & Indicator

Features:
- High Quality
- 5 Year Warranty
- High Accuracy +/-0.5C (0.9F), 0.03% Reading
- Full Autotune PID Control
- User Friendly, Simple to Configure
- Free Software, Active X Controls
- Universal Inputs: Thermocouple, RTD, Process Voltage/Current, Strain
- First 1/32 DIN Instrument with Totally Programmable Color Displays (Standard)
- Both RS-232 and RS-485 Serial Communications in One Instrument (Optional)
- Analog Output Selectable as a Control Output or as Retransmission of Process Variable
- Built-in Excitation, 24 V DC, Standard
- 2 Control or Alarm Outputs (Optional)
- DC Pulse - Solid State Relays (SSR's) - Mechanical Relays - Analog Voltage and Current
- NEMA-4, IP65 Front Bezel
The NEWPORT
® i32 is the iSeries meter/ controller in the extremely compact and increasingly popular 1/32 DIN size. The i32 is the most sophisticated and accurate instrument available in the small 1/32 DIN package, yet is still easy to configure. The i32 handles more thermocouple, RTD, process voltage and current inputs than any other 1/32 DIN controller. The i32 is the first 1/32 DIN controller with built-in excitation for transmitters or other devices, 24 Vdc @ 25mA. The iS32 has built-in excitation for bridge transducers, 5Vdc @ 40mA or 10 Vdc @ 60mA. When communications options are installed, external excitation may be used and ratiometric operation maintained by connecting the external excitation to the sense leads. Both 4 or 6-wire bridge configurations are supported for internal or external excitation. Nonratiometric operation is supported for voltage and current transducers and is also valuable in measuring offset and millivolt output of bridge devices during manufacturing and calibration. This model also features 10 Point Linearization which allows the user to linearize the signal input from extremely nonlinear transducers of all kinds. The i32 and iS32 introduce a number of unique features not yet found on any other 1/32 DIN instrument. The i32 and iS32 are the first 1/32 DIN controllers with a totally programmable display that can change color at any set point or alarm point. The unique 9-segment LED characters greatly improves alphanumeric representations. The i32 and iS32 are the first 1/32 DIN controllers offering 2 SPDT (Single Pole Double Throw) Form C relays, instead of the single throw relays on typical 1/32 DIN controllers. The i32 and iS32 are the first to offer both RS-232 and RS-422/485 serial communications in one instrument (C24 option). Both ASCII protocol and modbus protocol are selectable from the menu.  The NEWPORT® iSeries are the first complete series of 1/8, 1/16 and 1/32 DIN process control instruments with totally programmable color displays. The display can be programmed to change color at any set point or alarm point. For example, the instrument can be programmed to display the process value in GREEN during warm-up, switching to AMBER to signal the normal operating range, and in RED to signal an alarm condition. The changes in color are quickly seen from a distance, and machine operators can intuitively react to changing conditions. The colors can be programmed to change back when the value drops back below the alarm point or to "latch" on until being reset by the operator. The instrument can also be programmed to display only one unchanging color: GREEN,AMBER, or RED. This is a useful way to let an operator identify, at a glance, process values in three separate locations, or to display three different measurements such as Temperature, Pressure, and Flow.   Specifcations: Common Specifications: Accuracy: +/-0.5C temp; 0.03% reading process Resolution: 1/0.1; 10 uV process Universal Temperature & Process Input (Model "i") Temperature Stability: 1) RTD: 0.04C/C 2) TC: @25C (77F): 0.05 C/C - Cold Junction Compensation 3) Process: 50 ppm/C NMRR: 60 dB CMRR: 120 dB A/D Conversion: Dual slope Reading Rate: 3 samples per second Digital Filter: Programmable Display: 4-digit, 9-segment LED • 10.2 mm (0.40"): i32, i16, i16D (Dual Display), i8DV (Dual Vertical) • 21 mm (0.83"): i8 • 10.2 mm (0.40") and 21 mm (0.83"): i8DH (Dual Horizontal) Red, green and amber programmable colors for process variable, set point and temperature units Input Input Types: Thermocouple, RTD, Analog Voltage, Analog Current Thermocouple Lead Resistance: 100 ohm max Thermocouple Type (ITS 90): J, K, T, E, R, S, B, C, N, L RTD Input (ITS 68): 100/500/1000 ohm Pt sensor, , 3- or 4 wire; 385 or 392 curve Voltage Input: 0 to 100 mV, 0 to 1 V, 0 to 10 Vdc Input Impedance: 10 Mohm for 100 mV, 1 Mohm for 1 or 10 Vdc Current Input: 0 to 20 mA (5 ohm load) Configuration: Single-ended Polarity: Unipolar Step Response: 0.7 sec for 99.9% Decimal Selection: None, 0.1 for temperature; None, 0.1, 0.01 or 0.001 for process Setpoint Adjustment: -1999 to 9999 counts Span Adjustment: 0.001 to 9999 counts Offset Adjustment: -1999 to +9999 Universal Strain & Process Input (Model "iS") Accuracy: 0.03% reading Resolution: 10/1uV Temperature Stability: 50 ppm/C NMRR: 60 dB CMRR: 120 dB A/D Conversion: Dual slope Reading Rate: 3 samples per second Digital Filter: Programmable Input Types: Analog Voltage, Analog Current Voltage Input: 0 to 100 mVdc, -100 mVdc to 1 Vdc, 0 to 10 Vdc Input Impedance: 10 Mohm for 100 mV; 1 Mohm for 1 V or 10 Vdc Current Input: 0 to 20 mA (5 ohm load) Linearization Points: Up to 10 Linearization Points Configuration: Single-ended Polarity: Unipolar Step Response: 0.7 sec for 99.9% Decimal Selection: None, 0.1, 0.01 or 0.001 Setpoint Adjustment: -1999 to 9999 counts Span Adjustment: 0.001 to 9999 counts Offset Adjustment: -1999 to +9999 Excitation (optional in place of Communication): 5 Vdc @ 40 mA; 10 Vdc @ 60 mA. Control Action: Reverse (heat) or direct (cool) Modes: Time and Amplitude Proportional Control Modes; selectable Manual or Auto PID, Proportional, Proportional with Integral, Proportional with Derivative with Anti-reset Windup and ON/OFF Rate: 0 to 399.9 seconds Reset: 0 to 3999 seconds Cycle Time: 1 to 199 seconds; set to 0 for ON/OFF operation Gain: 0.5 to 100% of span; Setpoints 1 or 2 Damping: 0000 to 0008 Soak: 00.00 to 99.59 (HH:MM), or OFF Ramp to Setpoint: 00.00 to 99.59 (HH:MM), or OFF Auto Tune: Operator initiated from front panel Control Output 1 & 2 Relay: 250 Vac or 30 Vdc @ 3 A (Resistive Load); configurable for on/off, PID and Ramp and Soak Output 1: SPDT type, can be configured as Alarm 1 output Output 2: SPDT type, can be configured as Alarm 2 output SSR: 20-265 Vac @ 0.05 - 0.5 A (Resistive Load); continuous DC Pulse: Non-Isolated; 10 Vdc @ 20 mA Analog Output (Output 1 only): Non-Isolated, Proportional 0 to 10 Vdc or 0 to 20 mA; 500 ohm max Network and Communications (Optional) Ethernet:Standards Compliance IEEE 802.3 10Base-T Supported Protocols: TCP/IP, ARP, HTTPGET RS-232/RS-422/RS-485/MODBUS Selectable from menu; both ASCII and modbus protocol selectable from menu. Programmable 300 to 19.2 K baud; complete programmable setup capability; program to transmit current display, alarm status, min/max, actual measured input value and status RS-485: Addressable from 0 to 199 Connection: Screw terminals Alarm 1 & 2 (programmable) Type: Same as Output 1 & 2 Operation: High/low, above/below, band, latch/unlatch, normally open/normally closed and process/deviation; front panel configurations Analog Output (programmable): Non-Isolated, Retransmission 0 to 10 Vdc or 0 to 20 mA, 500 ohm max (Output 1 only). Accuracy is +/-1% of FS when following conditions are satisfied. 1) Input is not scaled below 1% of Input FS. 2) Analog Output is not scaled below 3% of Output FS. EXCITATION (not included with Communication): 24 Vdc @ 25 mA (Not Available for Low Power Option) Insulation Power to Input/Output: 2500 Vac per 1 minute test For Low Voltage/Power Option: 1500 Vac per 1 minute test Power to Relay/SSR Outputs: 2500 Vac per 1 minute test Relay/SSR to Relay/SSR Outputs: 2500 Vac per 1 minute test RS-232/485 to Inputs/Outputs: 500 Vac per 1 minute test Approvals: UL, C-UL, CE per EN50081-1, EN50082-2, EN61010- 1 General Line Voltage/Power: 90-240 Vac +/-10%, 50-400 Hz*, 110-375 Vdc, equivalent voltage Low Voltage/Power Option: 24 Vac +/-10%, 12-36 Vdc, from qualified safety approved source Environmental Conditions: 0 to 50C (32 to 122F), 90% RH non-condensing: i8DV, i8DH, i16D; 0-55C (32-131F) 90% RH non-condensing: i/8, i/16, i/32. Installation Category: II per EN61010-1 Equipment Class: II per EN61010-1 Pollution Degree: 2 per EN61010-1 Protection: NEMA-4 (IP65) front bezel Dimensions i/8 Series: 48 H x 96 W x 127 mm D (1.89 x 3.78 x 5") i/16 Series: 48 H x 48 W x 127 mm D (1.89 x 1.89 x 5") i/32 Series: 25.4 H x 48 W x 127 mm D (1.0 x 1.89 x 5") Panel Cutout i/8 Series: 45 H x 92 mm W (1.772" x 3.622"), 1/8 DIN i/16 Series: 45 mm (1.772") square, 1/16 DIN i/32 Series: 22.5 H x 45 mm W (0.886" x 1.772"), 1/32 DIN Weight i/8 Series: 295 g (0.65 lb) i/16 Series: 159 g (0.35 lb) i/32 Series: 127 g (0.28 lb)
|
Product Reviews
|
|