Graphtec Petit LOGGER GL100-WL Wireless Data Logger w/ Voltage/Temp. Terminal

The GL100-WL data logger can connect up to 4ch of voltage DC (20mV to 50V as well as 1-5V) and thermocouple (K or T type) temperature measurement. Each voltage / temperature channel is configurable and the combination of pulse and logic channels can be measured at the same time.
Wireless access will support multiple configurations for both secured and world wide internet access

GL100-WL Features
- Modular
- Supports a variety of measurements by exchanging the input module
- PC and smart mobile device software available
- Industry-specific software: agriculture, logistics, power
- Wireless access for GL100-WL model
- Built-in memory ~4.9MB
- microSD memory card port
Applications

Technical Specifications
|
Specifications of GL100-WL, GL100-N
|
|
Item
|
Description
|
|
Number of channel
|
Up to 4 channels (varies by the type of input module used, and measurement type is fixed with each input module.)
|
|
Interface to PC
|
USB 2.0, Wireless LAN (IEEE802.11b) in GL100-WL
|
|
Functions
|
• Real-time data capturing • Display the captured data value to the LCD in real-time and save the monitoring values • Set conditions using the Menu setting
|
|
While using Wireless LAN: • Output captured data in real-time • Output the saved data from the internal memory • Full control of the GL100 from the PC application software • Send warnings via the e-mail in GL100-WL (*¹)
|
|
While using USB port: • Output captured data in real-time • Output the saved data from the internal memory • Full control of the GL100 from the PC application software
|
|
Display
|
LCD (backlit monochrome, graphical type)
|
|
Storage device
|
• Built-in RAM (Approx. 4.9 MB) • micro SD memory card * Maximum file size for captured data is 1.9 GB.
|
|
Sampling interval
|
0.5 to 30 seconds and 1 to 60 minutes
|
|
Output signal
|
Alarm (1 channel), Warnings message is sent via the e-mail in GL100-WL (*¹)
|
|
Power source
|
• Battery (AA x 2) • USB bus-power (micro USB connector) * The required power capacity is 5V, 1A when AC adapter for microUSB drive is used. AC adapter is not included.
|
|
Operating environment
|
Temperature: -10 ºC to 50 ºC Humidity: up to 80% RH (non condensed) Water resistance: IP54
|
|
External dimension
|
Approx. 66 x 100 x 27 mm (exclude protrusion)
|
|
Weight
|
GL100-N: Approx. 125 g, GL100-WL: Approx. 130 g
|
|
Software
|
|
Item
|
Description
|
|
Supported OS
|
Windows: 8.1 / 8 / 7 / Vista (32- or 64-bit), Android OS: 4.3 or later, iOS: 7 or later
|
|
Controlled units
|
Up to 10 units
|
|
Accessories
|
|
Item
|
Model number
|
Description
|
|
Thermistor sensor (Normal type)
|
GS-103AT-4P
|
Sensor for GS-4TSR module, 3 m, 4 pcs/set, Temp. range: -40 to 105 ºC
|
|
Thermistor sensor (Ultrathin type)
|
GS-103JT-4P
|
Sensor for GS-4TSR module, 3 m, 4 pcs/set, Temp. range: -40 to 120 ºC
|
|
AC Current sensor
|
GS-AC50A
|
For GS-DAP-AC module, Cable 200 mm, Current range : 50 A AC
|
|
AC Current sensor
|
GS-AC100A
|
For GS-DAP-AC module, Cable 200 mm, Current range : 100 A AC
|
|
AC Current sensor
|
GS-AC200A
|
For GS-DAP-AC module, Cable 200 mm, Current range : 200 A AC
|
|
Dual port adapter
|
GS-DPA
|
Connect up to two (2) sensors
|
|
Module Extension Cable
|
GS-EXC
|
Extension cable for input module, 1.5 m long
|
|
Item
|
Description |
|
GS-4VT
|
|
| |
|
Measurement Data
|
Voltage / Tempaerature, Logic / Pulse (instant, accumulated) |
| |
|
Measurement channels
|
Voltage / Temperature 4ch Logic / Pulse 4ch |
|
Voltage Measurement Range
|
20 | 50 | 100 | 200 | 500mV 1 | 2 | 5 | 10 | 20 | 50V 1-5FV F.S. |
|
Voltage Measurement Degree of Accuracy
|
0.15% of F.S. |
|
Input Impedence / Input Method
|
1Ω±5% / Scan by means of photo-memory, full channel input disconnection
|
|
Temperature Coefficient
|
Amplification: 0.01% of F.S./ºC Zero: 0.02% of F.S./ºC
|
|
Permitable Signal Resistance
|
300Ω and below
|
|
Maximum Input Voltage
|
Input Terminal + / – Interval: 60Vp-p Input Terminal / Input terminal interval: 60Vp-p Input Terminal / GND Interval: 60Vp-p |
|
Voltage-Proofing
|
Input Terminal / Input terminal interval: 350Vp-p 1 Minute Input Terminal / GND interval: 350Vp-p 1 Minute |
|
Insulation Resistance
|
Input Terminal / GND interval: 50MΩ and greater (at DC500V) |
|
Common Mode Removal Ratio
|
90dB and greater (50/60Hz source signal 300Ω and lower) |
|
Noise
|
48dB and greater (+ / – at short) |
|
Range of Temperature Measurement
|
<Thermocouple> K: -200.0ºC~1370.0ºC T: -200.0ºC~400.0ºC |
Temperature Measurment Degree of Accuracy (Standard Compensation of ±0.5ºC) |
K-type Thermocouple |
-200≤TS≤-100 ± (0.05% of rdg +2.0ºC)
-100≤TS≤1370ºC ± (0.05% of rdg +1.0ºC)
|
T-type Thermocouple |
-200≤TS≤-100 ± (0.1% of rdg +1.5ºC)
-100≤TS≤400ºC ± (0.1% of rdg +0.5ºC)
|
|
Burnout Detection
|
Yes |
| Logic / Pulse Input |
Range of Input Voltage |
0 to +24V (Single line ground input) |
| Input Signal |
Wireless pressure point (a contact point, b contact point, NO, NC), open corrector, voltage input |
Input Voltage Threshold |
Approx. 2.5V |
| Hysterisis |
Approx. 0.5V (+2v to +2.5V) |
|
Range of Pulse Measurement
|
Instant: Maximum 200C / sampling Accumulated value: Maximum 65535C (clear accumulated value by QUIT key or when starting recording) |
|
Room Temperature Compensation
|
ON / OFF |
|
Temperature Unit of Denomination
|
ºC/ºF |
|
Sampling Intervals
|
0.5 | 1 | 2 | 5 | 10 | 20 | 30 sec 1 | 2 | 5 | 10 | 20 | 30 | 60 min
|
|
Extension Cable
|
Approx. 20cm |
|
Operating Environment
|
-10º to 50ºC, 80% RH and below (dew-less) |
|
External Dimensions
|
46mm x 66mm x 35.5mm (excludes protrusion) |
|
Weight
|
85g (2.99 oz) |
|